5.2.1 Unit location selection can refer to installation manual
5.2.2 DO NOT install the unit in the following locations:
5.2.3 The minimum distance between the outdoor unit and walls described in the installation
guide does not apply to airtight rooms. Be sure to keep the unit unobstructed in at least two
of the three directions (M, N, P)
M
N
P
30
cm
/
11.8”from
back
wall
60
cm
/
23.6”on
right
60 cm / 2 3 . 6aboev
30
cm
/
11.8”on
left
200
cm
/
78”in
front
5.2.4 Rows of series installation
The relations between H, A and L are as follows.
L
A
L H
L 1/2H
25 cm / 9.8 or more
1/2H < L ≤ H
30 cm / 11.8 or more
L > H
Can not be installed
DO NOT install the rows of series like above figure.
5.2 Location selection
Where oil drilling or fracking is taking place.
Costal areas with high salt content in the air.
Areas with caustic gases in the air, such as near hot springs.
Areas with power fluctuations, such as factories.
Enclosed spaces, such as cabinets.
Rooms with high humidity, such as bathrooms or laundry rooms.
Areas with strong electromagnetic waves and areas that store flammable materials or gas.
If possible, DO NOT install the unit where it is exposed to direct sunlight.