BLU 5000.1 PR / MD
BLU 6000.1 PR / MD
G20 - 70÷300 mbar
LB 832
28.04.2004
GASTEC
A BRUCIATORI A GAS PROGRESSIVI E MODULANTI
B
MODULATING AND PROGRESSIVE GAS BURNERS
C BRULEURS GAZ PROGRESSIVES ET MODULANTS
D QUEMADOR DE GAS PROGRESIVOS EN MODULANTE
Question and Answer IconNeed help?

Do you have a question about the Ecoflam Blu 5000.1 PR and is the answer not in the manual?

Ecoflam Blu 5000.1 PR Specifications

General IconGeneral
BrandEcoflam
ModelBlu 5000.1 PR
CategoryBurner
LanguageEnglish

Summary

Installation and Initial Setup

Gas Pipeline Connection & Electrical Setup

Connecting gas pipeline, checking seals, and verifying electrical connections.

Burner Start-Up Procedure

Steps for initial burner start-up, including preliminary checks.

Combustion Adjustment

Guidelines for optimizing combustion and thermal capacity via analysis.

Operating Cycles and Components

Landis & Staefa LFL1.622 Operating Cycle

Illustrates normal and ignition failure operating cycles for the Landis & Staefa LFL1.622.

Air Damper Motor Components

Details on adjusting cams for the Landis & Staefa SQM 50.481A2 air damper motor.

Burner Air and Gas Adjustment

Capacity Adjustments (Min/Max/Intermediate)

Adjusting minimum, maximum, and intermediate burner capacities for air and gas.

Calculating Burner Capacity

Formula and process for calculating the burner's output capacity in kilowatts.

Combustion and Component Adjustment

Firing Head & Electrode Settings

Instructions for setting the firing head, ignition electrode, and ionization probe.

Pressure Switch Adjustments

Procedures for adjusting gas minimum and air pressure switches.

Control Panel and Burner Disassembly

Ionization Current Check

Method for measuring ionization current to ensure proper flame detection.

Firing Head Disassembly

Diagram showing the steps to disassemble the burner's firing head for maintenance.

Control Panel Components

Identification and description of the various components on the burner's control panel.

RWF 40 Microprocessor Regulator

Display and Key Description

Explanation of the RWF 40 regulator's display elements and key functions.

Programming Levels

Overview of the different menu levels for programming the RWF 40 regulator.

RWF 40 Regulator Parameter Settings

Set Point, PID, and Differential Settings

Modifying set points, PID parameters, and ignition/shutoff differentials.

Mode Selection and Climatic Compensation

Switching modes and configuring climate compensation with external probes.

Parameterization and Probe Connections

Heating Curve Gradients

Graphical data relating boiler temperature set point to external temperature and gradient.

Probe Connection Diagrams

Schematics detailing the correct wiring for various temperature and pressure probes.

Regulator Configuration and Faults

Input Configuration (C111-C112)

Configuration settings for analog inputs, setpoint, and unit address.

Auxiliary Contact and Set Point

Configuration of auxiliary contact type and set point interlock to external probe.

Error and Fault Indicators

Explanation of display errors (1999 blinks) and their causes/remedies.

Maintenance and Troubleshooting

Routine Maintenance

Annual checks and procedures for cleaning and inspecting burner components.

Pre-Action Checks

Essential safety and system checks before performing any maintenance or repair.

Burner Start-Up Troubleshooting

Diagnostic steps for common issues preventing burner start or operation.

Burner Parameters and Configuration

Parameter Definitions

Table detailing parameters, display codes, and default settings for different probes.

Configuration Settings

Configuration codes for analog inputs, setpoints, limits, and corrections.