Page #13 background imageLoading...
Page #13 background image
9
1. Turn the fuel cap breather valve knob to "ON". 2. Turn the Engine Switch to "ON".
The generator can be started using any of the four methods below:
a) Electric Start Switch
Press and hold the Electric Start Switch for 2 seconds to execute the
start-up program and start up the generator.
Tips: To save battery power consumption, when the Engine Switch is
at the "ON" position, if the generator fails to start up, the power will be
disconnected after 3 mins and the display screen will switch off. In this
situation, press the start button to activate the screen display to then re-
enable the Electric Start Switch.
b) Manual start
Pull the Manual Starter Grip until the line tightens and push it by force.
Tips: When starting by hand, it is necessary to hold the generator still to prevent it from tilting or
tumbling during the pull-push process.
c) Self-start, see paragraph 2.4.4
d) Starting through the app, see paragraph 2.4.5
Tips: When the ambient temperature is below 32
℉(
0 °C), the engine will need to warm up for three
minutes after being started, during which time no load should be loaded.
Read the Safety Guidelines before use.
Do not use the generator in a closed space as the exhaust fumes may result in a loss of
consciousness or even death. Use it in a well-ventilated place.
Do not connect the AC Output Socket with any electrical equipment before starting the generator.
Tips: The generator is used at 5
-104
(
-15
—40
℃).
The generator can operate at rated power under
standard atmospheric conditions (“standard atmospheric conditions” - ambient temperature 77
(25
℃)
- atmospheric pressure 100KPA - relative humidity 30%). Once the temperature, humidity and altitude
exceed standard atmospheric conditions, the output of the generator will drop. Using for a long time in
a high temperature (above 95
℉ /
35
)
environment will affect the service life of the generator and the
built-in battery. Moreover, if the generator is used in any narrow space, its load must be reduced as the
generator cooling is affected.
2.4 Using the Product
2.4.1 Startup
Manual start
Danger

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EcoFlow Smart Generator and is the answer not in the manual?

EcoFlow Smart Generator Specifications

General IconGeneral
Fuel typeLiquefied Petroleum Gas (LPG), Petrol
Noise level67 dB
Rated power1800 W
Cooling typeAir
Maximum power1900 W
Rated voltage230 V
Ignition systemManual/Electronic
Rated frequency50 Hz
Fuel consumption- l/h
Fuel tank capacity4 L
AC outlets quantity1 AC outlet(s)
Number of cylinders1
Engine number of strokes4
Continuous operating time @ maximum power @ rated voltage3.5 h
Castor wheelsNo
Product colorBlack
Oil tank capacity0.38 L
Carrying handle(s)Yes
Weight and Dimensions IconWeight and Dimensions
Depth597 mm
Width300 mm
Height475 mm
Weight30500 g