EasyManuals Logo

EcoFlow Smart Generator User Manual

EcoFlow Smart Generator
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
14
The carburetor is an important part of engine, and should be adjusted by the dealer who has the
professional knowledge, data and equipment to ensure it is adjusted correctly.
3.2 Adjusting the Carburetor
Usage in high altitude areas
In high altitude areas, the atmospheric pressure may reduce the amount of air intake, decline the performance
and increase the fuel consumption of standard carburetors. Moreover, the dense mixture may contaminate
the spark plug and lead to starting difficulties. When the generator is running at high altitudes (above 3000
feet/914 m), the emissions may increase.
Modifying the carburetor can improve its high altitude performance. If you plan to operate your generator at
high altitude (above 3000 feet/914 m) areas for a long time, please contact your after-sales service team to
help to modify it. When using the modified carburetor in high altitude areas (if within the service life of the
generator), the generator will satisfy every emission standard.
Standard spark plug: A5RTC
Spark plug clearance: 0.15–0.3 mm
Tips: The engine may be damaged if the spark
plug is not at the correct clearance height.
3.1 Checking the Spark Plug
Removing the
sparkplug
Spark plug clearance
1. Turn the maintenance cover knob to
and take off the maintenance
cover.
2. Take off the spark plug cap.
3. Use the spark plug socket and revolve it counterclockwise to remove
the spark plug.
4. Check for any fading in color and remove any carbon deposits. The
porcelain center around the spark plug center electrode should
be moderately light brown if it is in good condition. The electrode
should be replaced if worn, or if the insulation is peeling, cracked or
dirty.
5. Check the model of the spark plug and that it has sufficient
clearance. If required, correct the gap.
6. Reinstall the spark plug with a torque of 13.5±1.5 Nm.
Tip: If installing without a torque wrench, a good method is to tighten
until tight, then continue to turn by a further 1/4-1/2 rotation.
7. Reinstall the spark plug cap on the spark plug.
8. Reinstall the maintenance cover.
The spark plug is an important part of the generator and must be checked regularly.
0.15-0.3mm

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EcoFlow Smart Generator and is the answer not in the manual?

EcoFlow Smart Generator Specifications

General IconGeneral
Fuel typeLiquefied Petroleum Gas (LPG), Petrol
Noise level67 dB
Rated power1800 W
Cooling typeAir
Maximum power1900 W
Rated voltage230 V
Ignition systemManual/Electronic
Rated frequency50 Hz
Fuel consumption- l/h
Fuel tank capacity4 L
AC outlets quantity1 AC outlet(s)
Number of cylinders1
Engine number of strokes4
Continuous operating time @ maximum power @ rated voltage3.5 h
Castor wheelsNo
Product colorBlack
Oil tank capacity0.38 L
Carrying handle(s)Yes
Weight and Dimensions IconWeight and Dimensions
Depth597 mm
Width300 mm
Height475 mm
Weight30500 g

Related product manuals