5
Figure 4-1
4.0 INSTALLATION PROCEDURES
4.1 Pre-Planning the Installation
There is no substitute for planning the installation prior to
beginning the work, minutes in planning may save hours in
installation time. The following items should be taken into

Allow visual displays on the front of the cabinet to be in
full view of the operator.
Permit shortest possible tube, wire, and conduit
lengths
Provide accessibility for adjustments and servicing.
 
heat as possible.
The following items should be taken into consideration before
installing the Sensor. The sensor should be located in an

A minimum 2" (5 cm) from the tank bottom, sidewall,

As far as possible (2" minimum) (5 cm) from heater
elements or coils.
Protection from physical hazards.
For constant submersion of all parts of the sensor in
the wash water. This is a particular concern on shallow
tank machines.
NOTE: The S-2000 Sensor is provided with a 12' cable
and mounts from the inside of the washtank. Sufcient
clearance on the inside is required to allow insertion/
removal of the sensor.
NOTE: A S-2000 sensor with 24' cable is available where
necessary (9212-2316).
4.2 Installing the Transformer
1. Mount the plastic transformer enclosure assembly into
the plastic GeoCenter enclosure. (Refer to Figure 4-1).


4.3 Mounting the GeoCenter
1. Mount the GeoCenter cabinet to the wall using the
supplied screws, washers and plastic wall anchors. The
GeoCenter cabinet may also be installed on top of the
dish machine, using the universal mounting brackets,
and may be the preferred location in some installations.
The installa
tion should be secure, neat and square, refer to
Figure 4-1.
4.4 Mounting Sensor in Wash Tank
Review Item 4.1, Pre-planning the Installation, before the
installation begins.
IMPORTANT: Before drilling the hole check for
obstructions both inside and outside of the wash
tank.
 
SCREW


2. Properly DEBURR the hole.
3. Attach the sensor connector to the tank using the pro-
vided metal lock nut and the stainless steel and rubber
washers on both the inside and outside surfaces of
the tank wall. Regardless of which sensor is used, the
packing nut end of the tank connector must be on the
outside of the machine wall, refer to Figure 4-2.
4. Position the sensor by sliding it through the connector
opening and tightening the packing nut.
4.5 Geosystem Detergent Dispenser
Installation
1. Install the desired Geosystem Detergent Dispenser
following the installation instructions provided for that
unit.
4.6 VANGUARD Wash Max Installation
1. Install the desired VANGUARD Wash Max following the
installation instructions provided for that unit.
S-2000 SENSOR
SENSOR
CABLE


Figure 4-2