What to do if Ecolab VANGUARD WASH MAX Industrial Equipment has inadequate water flow to the dishmachine?
- BbrowningstephanieAug 8, 2025
If there's little to no effluent flow, first ensure the reservoir cover is completely closed to engage the safety switch. Then, verify that all shut-off valves and the needle valve at the water source are fully open. Check for 24 volts at the solenoid valve coil; if absent, refer to Step C for 'NO POWER TO SOLENOID'. If voltage is present, confirm the valve is opening; if not, it's likely defective and needs replacement. Also, inspect for any blockages in the water line, solenoid valve/line strainer, and the vacuum breaker. Finally, check the spray nozzle for damage and the product outlet tubing for blockages.