EasyManua.ls Logo

Ecosoft FPA Series - Page 21

Ecosoft FPA Series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
INSTRUCTION MANUAL ECOSOFT
®
MEDIA SYSTEMS
Model range
Model
Overall dimensions, m
(width × depth × height)
Nominal ow rate, m
3
/h
Quantity of media, L
Consumption of water
per regeneration, m
3
Required ow capacity,
m
3
/h
1
FP-1035 0,3×0,3×1,1 0,6 28,3 0,3-0,5 1,2
FP-1054 0,3×0,3×1,6 0,6 28,3 0,3-0,5 1,2
FP-1252 0,4×0,4×1,6 0,9 56,6 0,5-0,7 1,7
FP-1354 0,4×0,4×1,6 1,0 56,6 0,5-0,8 2,0
FP-1465 0,4×0,4×1,9 1,2 84,9 0,6-0,9 2,3
FP-1665 0,5×0,5×1,9 1,6 113,2 0,8-1,2 3,0
FP-2162 0,6×0,6×2,0 2,6 141,5 1,2-1,8 4,5
1
supply water ow rate required for proper regeneration of system
Ecosoft FP
®
ltration systems
Requirements and limitations
Installation room
Ambient temperature +5°C…+40°C
Relative humidity ≤80%
Operating environment
indoor; free of corrosive vapors, airborne dust,
and brous matter; sheltered from weather
and direct sunlight
Power supply
Electrical rating 230 V, 50 Hz (EU adapter)
Power 6 VA
Water supply
Pressure 2-6 bar (30-90 psi)
Water temperature +4°C…+30°C
Prelter rating 100 μm