INSTRUCTION MANUAL ECOSOFT
®
MEDIA SYSTEMS
6. SPECIFICATIONS
Ecosoft FK
®
Ecomix systems
Requirements and limitations
Installation room
Ambient temperature +5°C…+40°C
Relative humidity ≤80%
Operating environment
indoor; free of corrosive vapors, airborne dust,
and brous matter; sheltered from weather
and direct sunlight
Power supply
Electrical rating 230 V, 50 Hz (EU adapter)
Power 6 VA
Water supply
Pressure 2-6 bar (30-90 psi)
Water temperature +4°C…+30°C
Prelter rating 100 μm
Maximum inuent concentrations
Hardness
750 mg CaCO
3
/L
42 °dH
45 gpg
Iron 15 mg/L
Manganese 3 mg/L
Ammonia 4 mg/L
Chemical oxygen demand 20 mg/L O
2
Total dissolved solids 4000 mg/L