INSTALLER AND USER GUIDE FOR REVERSE OSMOSIS SYSTEM ECOSOFT ROBUST 1000, ROBUST 3000
Figure 4. Operang parameters of the system.
* Skip if using a tankless system.

6. OPERATION
1. Use calibrated TDS meter to test total dissolved solids in tap and puried water.
Write down the readings in the maintenance log.
2. Verify proper funconing of feed water solenoid. The system must switch o and stop
discharging concentrate when pressure tank is full* and puried water faucet is closed.
3. Inspect the system carefully for leaks.
4. Advise the system’s owner how to operate and maintain the system, refer to this manual.
5. Make a record of system installaon in the maintenance log.
6*. When using a pressure tank, note that the tank is full when high-pressure switch is
acvated, pump switches o and concentrate stops running to drain. The me to ll the tank
depends on water pressure at the tapping point.
RObust should be used for puricaon of cold water only. If puried water ow rate has decreased
or tank is taking longer than normal to ll, the likelihood is that pre-lter is clogged and need to be
replaced as soon as possible.
Delayed replacement of pre-lters can result in damage or failure of the membranes. In order to
avoid this, it is recommended to replace pre-lters at least once in three months of connuous use.
If puried water ow rate drops signicantly and is not caused by pre-lter wear or abnormal op-
erang condions, the array of membranes has to be replaced. For best puried water quality,
replace membranes at least once a year.
If the system is to be out of operaon for two weeks or longer, sanize the system as described in
secon 7. When disconnuing use of the system, it is recommended to shut o the water supply.
   
st
  If pressure aer pre-lters is less than 1 bar
(14.5 psi), this may indicate low mains pressure or clogged pre-lters. Test pressure at the feed
adapter site. If it exceeds reading on the pressure gauge signicantly, replace pre-lters. Otherwise,
low feed water pressure is at fault and has to be sorted out. If the 1
st
pressure gauge displays over 5 bar
(72.5 psi) aer the system switches on, power down the system immediately, disconnect water sup-
ply, and install a pressure regulator upstream of the system. Then, connue seng up the system.
Maximum recommended feed water pressure is 3.5 bar (51 psi).
14.5 psi 58 psi
72.5 psi 101.5 psi

Other manuals for Ecosoft ROBUST 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ecosoft ROBUST 1000 and is the answer not in the manual?

Ecosoft ROBUST 1000 Specifications

General IconGeneral
BrandEcosoft
ModelROBUST 1000
CategoryWater Dispenser
LanguageEnglish

Related product manuals