Chapter 1
| Switch Description
Key Technical Specifications
– 15 –
* Testing Environment: 370 W (0-50° C), 740 W (0-45° C).
Power Consumption ECS2100-10T: 8 W
ECS2100-10P: 160 W
ECS2100-10PE: 80 W
ECS2100-28T: 20 W
ECS2100-28P: 260 W
ECS2100-28PP: 490 W
ECS2100-28PP+ one external power supply: 950 W
ECS2100-52T: 40 W
ECS2110-26T: 20 W
Weight ECS2100-10T: 816 g (1.8 lb)
ECS2100-10P: 2.4 kg (5.34 lb)
ECS2100-10PE: 973 g (2.15 lb)
ECS2100-28T: 2.2 kg (4.86 lb)
ECS2100-28P: 2.8 kg (6.18 lb)
ECS2100-28PP: 3.1 kg (6.85 lb)
ECS2100-52T: 2.5 kg (5.5 lb)
ECS2110-26T: 2.2 kg (4.85 lb)
Size (W x D x H):
ECS2100-10T: 19.64 x 11.71 x 3.66 cm (7.73 x 4.61 x 1.44 in.)
ECS2100-10P: 33.0 x 20.4 x 4.26 cm (12.99 x 8.03 x 1.67 in.)
ECS2100-10PE: 24.0 x 15.5 x 2.65 cm (9.44 x 6.10 x 1.04 in.)
ECS2100-28T/28P/28PP/52T, ECS2110-26T: 44 x 22 x 4.4cm (17.32 x
8.66 x 1.73 in. )
Temperature Operating: 0° C to 50° C (32° F to 122° F)
Operating: 0° C to 45° C (32° F to 113° F, ECS2100-28PP@370 W)*
Operating: 0° C to 40° C (32° F to 104° F, ECS2100-28PP@740 W)
Operating: 0° C to 40° C (32° F to 104° F, ECS2100-10P only)
Storage: -40° C to 70° C (-40° F to 158° F)
Humidity Operating: 10% to 90% (non-condensing)
Out-of-Band Management Front panel RJ-45 console port
In-Band Management SSH, Telnet, SNMP, or HTTP
Software Loading HTTP, FTP/TFTP in-band
Forwarding Mode Store-and-forward
Throughput Wire speed
Flow Control Full Duplex: IEEE 802.3x
Half Duplex: Back pressure
Table 1: Key Technical Specifications (Continued)
Item Specification