Chapter 5
| SNMP Commands
SNMPv3 Commands
– 217 –
need to configure the remote agent’s SNMP engine ID before you can send
proxy requests or informs to it.
Example
Console(config)#snmp-server user steve group r&d v3 auth md5 greenpeace priv
des56 einstien
Console(config)#snmp-server user mark group r&d remote 192.168.1.19 v3 auth
md5 greenpeace priv des56 einstien
Console(config)#
snmp-server view This command adds an SNMP view which controls user access to the MIB. Use the
no form to remove an SNMP view.
Syntax
snmp-server view view-name oid-tree {included | excluded}
no snmp-server view view-name
view-name - Name of an SNMP view. (Range: 1-32 characters)
oid-tree - Object identifier of a branch within the MIB tree. Wild cards can be
used to mask a specific portion of the OID string. (Refer to the examples.)
included - Defines an included view.
excluded - Defines an excluded view.
Default Setting
defaultview (includes access to the entire MIB tree)
Command Mode
Global Configuration
Command Usage
Views are used in the snmp-server group command to restrict user access to
specified portions of the MIB tree.
The predefined view “defaultview” includes access to the entire MIB tree.
Examples
This view includes MIB-2.
Console(config)#snmp-server view mib-2 1.3.6.1.2.1 included
Console(config)#