EasyManua.ls Logo

Edge-Core ECS4620-28F-2AC - Page 452

Edge-Core ECS4620-28F-2AC
1260 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 11
| Interface Commands
Power Savings
– 452 –
determine whether or not it can reduce the signal amplitude used on a
particular link.
Note:
Power savings can only be implemented on Gigabit Ethernet ports using
twisted-pair cabling. Power-savings mode on a active link only works when
connection speed is 1 Gbps, and line length is less than 60 meters.
Example
Console(config)#interface ethernet 1/24
Console(config-if)#power-save
Console(config-if)#
show power-save This command shows the configuration settings for power savings.
Syntax
show power-save [interface interface]
interface
ethernet unit/port
unit - Unit identifier. (Range: 1-8)
port - Port number. (ECS4620-28F/28F-DC: 23-24,
Other models: 1-24/48)
Command Mode
Privileged Exec
Example
Console#show power-save interface ethernet 1/24
Power Saving Status:
Ethernet 1/24 : Enabled
Console#

Table of Contents

Other manuals for Edge-Core ECS4620-28F-2AC

Related product manuals