Door Lock Error – Door Will Not Lock (E30)
Door will not lock (E30)
Is door closed correctly?
Check the wire connection.
Is the terminal connected correctly?
Check wires for open circuit.
Check the Door Lock
Replace Lock
Replace the PCBs
Step 1: Check the resistance between Pin 2 and Pin 3 with the Slipper
Held right as figure below. It should be in range from 30 to 100Ω.
Otherwise, the lock is failing.
Step 2: Hold the Locker Slip Left as figure above. Give a power pulse to
the Lock between Pin 2 and Pin 3. Then release the Slipper. It should
take the place without any movement. Otherwise, the lock is failing.
NOTE: The power pulse to the Lock should be less than ONE second.
Otherwise, it will be damaged.
Step 3: Give a power pulse to the Lock between Pin 2 and Pin 3 again.
The slipper should move back to its original place immediately.
Otherwise, the lock is failing.