The Unit Body
is Electrified
The ground plug is broken.
Adjust, reconnect
/replace wires.
Shorted electric component.
Scales Occur
Frequently
Inside Unit
The water quality is poor.
Install a water-softener or
water filter in front of the
water inlet valve.
Defective water inlet valve.
Replace the water inlet
valve.
Excessive noise/vibration.
Tighten compressor bolts
or replace the
compressor.
Refrigeration pipes vibrating.
The feet are not leveled.
The fan motor is loose or
defective.
Repair or replace the fan
motor.
Water Leaking
Out of Unit
Water connection leaking.
Tighten fitting. See
“Connecting the water
line.”
Drain pipe connection leaking.
Tighten fitting. See
“connecting the drain.”
Ice Harvesting
is Difficult
The hot gas valve damage.
Replace the hot gas
valve.
The evaporator is dirty or finish
is damaged.
Clean the ice mold, or
replace the evaporator.
Ambient Room and
Water Temperature
See “Ice Cube Size
Adjustment Guidelines” in
this manual.
Ice slide way is installed
incorrectly.
Reinstall ice slide so
harvested ice does not
get stuck or blocked.