CHARACTERISTICS
7+(5027(&+1,&$/&+$5$&7(5,67,&6DFFRUGLQJWR(1
Nominal power 6,5 kW
Ef¿ciency nominal power 91 %
Emissions &O (1% O2) nominal power 0,015 %
Smoke mass nominal power 6 gs
Reduced power 2kW
Ef¿ciency reduced power 9 %
Emissions &O (1% O2) reduced power 0,00%
Smoke mass reduced power 4,6 gs
Ma[imum overheated smoke 220 &
Minimum draught 12 3a
Autonomy (minma[) 12 6 hours
Fuel consumption (minma[) 0,5 1,5 kgh
&apacità serbatoio 18 kg
+eatable volume * 170 m
Weight including packaging (glasssteel) 170 18 kg
Smoke outlet pipe diameter (male) 80 mm
Air intake pipe diameter (male) 40 mm
* 7he heatable room dimensions are calculated on the basis home insulation in compliance with Italian law 1091, and subsequent
changes together with an e[pected heat output of Kcalmñ per hour.
ELECTRICAL CHARACTERISTICS
3ower supply 209ac - 10% 50 +z
Onoff switch Yes
Average power consumption 100 W
3ower consumption during ignition 400 W
Remote control frequency Radio waves 2,4 *+z
3rotection on mains power supply* (see page 25) 2A7, 250 9ac, 5[20 Fuse
3rotection on electronic circuit board 2A7, 250 9ac, 5[20 Fuse
1%
NHHSLQPLQGWKDWH[WHUQDOGHYLFHVFDQFDXVHLQWHUIHUHQFHWRWKHRSHUDWLRQRIWKHFLUFXLWERDUG
FDXWLRQOLYHSDUWV6HUYLFLQJDQGRULQVSHFWLRQVPXVWEHFDUULHGRXWE\TXDOL¿HGVWDII
7KHGDWDVKRZQDERYHLVSXUHO\LQGLFDWLYH
(',/.$0,1VSDUHVHUYHVWKHULJKWWRFKDQJHWKHSURGXFWVDWLWVGLVFUHWLRQZLWKRXWQRWLFH
SAFETY DEVICES
7+(502&283/(
3laced at the smoke outlet to detect the temperature.
7urns the stove on and off and controls its operation based on de¿ned parameters.
9$&880*$8*(
positioned on the smoke e[tractor, which detects the vacuum value (compared to the installation environment) in the combustion
chamber.
$,5)/2:6(1625
located in the suction channel, it is activated when the combustion air Àow is not correct, with consequent pressure problems in
the smoke circuit causing the stove to shut-down.
6$)(7<7+(50267$7
7rips when the temperature inside the stove is too high. It stops pellet loading, causing the stove to go out.
6$)(7<35(6685(6:,7&+
7his is activated if the vacuum inside the combustion chamber is insuf¿cient for it to function correctly.