EasyManua.ls Logo

Edwards E2MO.7 - The Vacuum Is Not Maintained after the Pump Is Switched off; The Pumping Speed Is Poor; There Is an External Oil Leak

Edwards E2MO.7
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The electrical supply voltage is too high.
The exhaust lter or exhaust line is blocked.
The oil level is too low.
The pump is lled with the wrong type of oil.
The oil is contaminated.
The process gas is too hot or the throughput is too high.
7.5 The vacuum is not maintained aer the pump is switched o
The gas-ballast control is open.
O-ring(s) are damaged or missing.
The sha seals have deteriorated.
7.6 The pumping speed is poor
The connecng pipelines are too small in diameter.
The connecng pipelines are too long.
The inlet-lter is blocked.
7.7 There is an external oil leak
The oil pump sha seal is worn or damaged.
The oil box gasket has deteriorated.
There is an oil leak from gas-ballast control.
There is an oil-leak from the drain-plug.