A546–00–880 Issue C
Page 8 © Edwards Limited 2008. All rights reserved.
Edwards and the Edwards logo are trade marks of Edwards Limited.
Technical Data
2.2 Electrical Data
2.3 Loading
Figure 6 - Centre of gravity and levelling foot loads
Tabl e 3 - E lect r i cal d at a
Supply voltage and frequency
200/230 50/60 Hz 380/460 50/60Hz
100 300 600 1000 100 300 600 1000
Full load (A) 12 22 22 22 8 14 14 14
Booster motor rating (kW)
1.9 1.9 1.9 1.9 1.9 1.9
Pump motor rating (kW) 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9
Tabl e 4 - C e nt re o f grav i t y a nd l e v elling foot loads (Refer to Figure 6)
100 300 600 1000
Centre of gravity
A 510 510 510 510
B 246 266 243 243
C 103 107 108 108
D 216 216 216 216
E 167 287 311 310
Levelling foot loads
1 26 45 56 56
2 35 58 55 55
3 28 43 61 61
4 31 54 48 48

Table of Contents