ELECTRIC INSTANTANEOUS WATER HEATER
INSTALLATION GUIDE AND OWNERS MANUAL
IF YOU REQUIRE ANY HELP OR HAVE ANY QUESTIONS RELATING TO THE
INSTALLATION OR PERFORMANCE OF THIS HEATER, PLEASE CALL OUR
TECHNICAL SERVICE DEPARTMENT TOLLFREE : 1-800-543-6163.
HAVE THE INFORMATION LISTED BELOW BEFORE CALLING :
SERIAL NO. MODEL NO. INSTALLATION DATE
EEMAX “THREE MODULE, SINGLE PHASE”
WATER HEATERS
MODELS COVERED:- EX230T2T 208/240V
EX280T2T 208/240 V
SPECIAL_________,______V
READ THE GENERAL SAFETY SECTION BEGINNING ON THE INSIDE COVER
AND THEN THIS ENTIRE MANUAL BEFORE INSTALLING OR OPERATING THIS
WATER HEATER. IF YOU DON’T FOLLOW THE SAFETY RULES, THE UNIT WILL
NOT OPERATE PROPERLY AND IT COULD CAUSE DEATH, SERIOUS BODILY
INJURY AND/OR PROPERTY DAMAGE. READ ALSO THE ENCLOSED
WARRANTY CARD. WARRANTY OF THIS WATER HEATER WILL DEPEND ON
PROPER INSTALLATION AND OPERATION. THE WARRANTY SHALL BE VOID IF
THE DESIGN HAS BEEN ALTERED IN ANY WAY WHATSOEVER. THE
MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE FOR ANY DAMAGES
BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION AND
OPERATING INSTRUCTIONS OUTLINED ON THE FOLLOWING PAGES.
THE INSTALLATION MUST CONFORM WITH THE INSTRUCTIONS IN THIS
MANUAL; ELECTRIC COMPANY RULES; AND THE LOCAL CODES, OR IN
THE ABSENCE OF LOCAL CODES, WITH THE LATEST EDITION OF THE
NATIONAL ELECTRICAL CODE. THIS PUBLICATION IS AVAILABLE FROM
YOUR LOCAL GOVERNMENT OR PUBLIC LIBRARY OR ELECTRIC COMPANY
OR BY WRITING UNDERWRITERS LABORATORIES, 333 PFINGSTEN ROAD
NORTHBROOK, IL, 60062.
WARNING
1 REV 8/08

Questions and Answers

  • S
    sandraguerreroAug 10, 2025
    What to do if EemaX EX230T2T has no heat or low temperature with indicator light on?
    • K
      Kyle DavisAug 10, 2025
      If your EemaX Water Heater shows the indicator light is on, but there's no heat or the temperature is low, you can try the following: First, reduce the water flow using an outlet ball valve. Next, ensure the unit is connected to the correct voltage supply as specified on the rating label on the front cover. You may need to test the heating element. If you have a “T2T” model, turn both thermostat adjustment screws clockwise in small increments until the indicator light(s) remains on, but be careful not to force the screw past its stop position. Also, check if the ECO (High Limit Thermostat) has tripped and reset it by pushing the red button on each heater module.
  • C
    Christina MooreAug 25, 2025
    How to fix EemaX Water Heater when no heat indicator light is off?
    • J
      James BuchananAug 25, 2025
      If the heat indicator light is off on your EemaX Water Heater, first, ensure that the three main circuit breakers are turned on. Then, check for adequate water flow, ensuring it meets the minimum flow rate (0.75 gallons per minute for “T2T” models) and that the inlet filter screen is free of debris. Verify that the water connections are correct: cold water should enter on the right side, and hot water should exit on the left. You may also need to test the heating element with an ohmmeter; the resistance should be under 10 ohms. Finally, check if the ECO (High Limit Thermostat) has tripped and reset it by pushing the red button on each heater module.