EasyManua.ls Logo

EemaX FlowCo SPEX80 - Derated Performance Data; Maximum Derated Temperature Rise at Specified Flow Rate

EemaX FlowCo SPEX80
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
MAXIMUM DERATED TEMPERATURE RISE AT SPECIFIED FLOW RATE, °F (°C)
Base
Model*
240VAC heaters used at 208VAC
GPM (LPM)
0.2
(0.76)
0.25
(0.95)
0.3
(1.14)
0.4
(1.51)
0.5
(1.89)
0.7
(2.65)
0.8
(3.03)
1.0
(3.79)
1.5
(5.68)
SPEX35
-
-
60
(33)
45
(25)
36
(20)
26
(14)
22
(12)
18
(10)
12
(7)
SPEX48
-
-
-
61
(34)
49
(27)
35
(19)
31
(17)
25
(14)
16
(9)
SPEX55
-
-
-
-
56
(31)
40
(22)
35
(19)
28
(16)
19
(11)
SPEX65
-
-
-
-
-
48
(27)
42
(23)
33
(18)
22
(12)
SPEX75
-
-
-
-
-
55
(31)
48
(27)
38
(21)
26
(14)
SPEX95
-
-
-
-
-
-
61
(34)
49
(27)
32
(18)
*Special suffixed models (i.e. CA, etc.), will have identical temperature rises as their base model
-“Flow rate below turn on flow for this model
Note: The values shown above are only for comparison purposes.