EasyManua.ls Logo

EFF EFF 519 - Rotary Switch S2

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Settings – Parameterising
Rotary switch S2
0 Button function:
The lock disengages as long as you press the release button.
1 to E Release time:
When you press the release button, the lock will remain disengaged for this time.
Time setting:
Set value x 2
Example: 1 = 2 sec.; 2 = 4 sec. .. E = 28 sec.
3 Release time 6 sec.
F Changeover function (toggle function):
The lock disengages when you press the release button.
The lock re-engages when you press the release button again.
Page 40 D0038804