EasyManua.ls Logo

Effecta Pellets 222 - Trouble Shooting

Effecta Pellets 222
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se
20
Trouble shooting
Low room temperature - Incorrect set on shunt valve
- Radiator pump not activated
- Air in radiators
- Low boiler temp.
- Adjust
- Activate
- Vent the system
- Check burner/electrical heater
Burner ”puffs” at start - Incorrect start dose - Adjust start dose
The panel is ”black” - Overheating protection has tripped - Reset (pg 7)
Overheating protection on the
burner activated
- Low draft
- Burner filled with ash
- Check draft
- Clean burner
Ash is black, not grey/white - Poor combustion - Contact installer
Poor hot water capacity - Low boiler temp
- Ti high flow in the pipes/system
- Set the burners stop-temp higher
- Adjust the flow on the mixing valve
Soot in the boiler room - Leaking seals - Check seals, contact installer
High flue gas temperature - Sooty boiler
- Poor combustion
- Broken sensor
- Clean boiler
- Contact installer
- Contact installer
White smoke from the chimney - Low flue gas temperature
- To big chimney
- Rainwater in the chimney
- Cut turbulators/increase power
- Contact installer
- Mount a rain hood
The burner doesn´t start - Micro switch broken
- Overheating protection activated
- No fuel
- Check switch
- Reset protection
- Fill up with fuel
Fault Cause Action
There are actions that the end user can take to fix a disruption. However, a professional should
always be contacted before any adjustment is done.