Troubleshooting
Page 71
Error message on the
display
Error
code
Solution
Interruption:
Device frozen. Please
defrost device slowly
for at least 24h at room
temperature.
40
The device was exposed to tem-
peratures below 1°C/34°F with-
out a connected battery and/or
an EFOY fuel cartridge that was
not filled sufficiently. It must be
allowed to defrost for approx. 24
hours at room temperature.
Interruption: Sur-
roundings too warm.
Please wait for the de-
vice to cool down.
41
The ambient temperature is too
high. The device will start auto-
matically if the temperature
drops to below 50°C/122°F.
Battery voltage low.
Please check battery
connection and load
battery.
50
52
Please check the cabling and
check whether a suitable battery
is connected. Check the battery
voltage. If it is too low, please
load the battery with a battery
charger. Please also check other
loading devices for defects, e.g.
alternator or charge controller.
Battery voltage high. If
applicable, please
check additional charg-
ing devices.
51
53
Please check the cabling and
check whether a suitable battery
is connected. Please also check
other loading devices for de-
fects, e.g. alternator or charge
controller.
Please disconnect fuel
cartridge connection,
shake cartridge firmly
and reconnect. Restart
device at most 2 times.
Press OK for restart.
72
Check the fuel cartridge connec-
tion and, if necessary, check for
any contamination and remove
it. Then please perform a system
reset (max. twice). If the error
still occurs, please contact your
service partner or the hotline.
Contact details are provided in
chapter 1.2 "Contact details" on
page 4.