Clearing House Codes: The House Codes memorised can be deleted (i.e. the
RadioLINK Bases can be uncoded) by pressing and holding the House Code
switch on for about 6 seconds. The amber light comes on solidly, then flashes
rapidly and stops. Release the House Code switch. The RadioLINK Base has now
been returned to the default factory setting.
All Ei168RC Bases are set as “Repeater” Bases as standard. The function of a
Repeater Base is to receive and then re-transmit the RF signals. This provides
multiple possible signal paths to give increased reliability. A maximum of ten
RadioLINK Bases can be set as Repeaters in any one system.
De-activating the Repeater function:
Press and hold the test button on the alarm until it sounds and the amber light on
the side of the RadioLINK base illuminates. Immediately (while amber light is still
on) press and hold the House Code switch on the side of the RadioLINK Base with
a small screwdriver until the amber light starts to flash slowly. Release the switch.
The amber light will flash slowly a total of four times and then stop. This indicates
that the Repeater mode has been deactivated.
Re-activating the Repeater function:
Press and hold the test button on the alarm until it sounds and the amber light on
the side of the RadioLINK base illuminates. Immediately (while amber light is still
on) press and hold the House Code switch on the side of the RadioLINK Base with
20