EasyManua.ls Logo

EINHELL 41.704.45 - Troubleshooting Guide

EINHELL 41.704.45
118 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB
- 20 -
11. Troubleshooting guide
Faults Cause Remedy
The equipment
does not start
- Power supply not connected
- Floating switch does trigger
- Check power supply
- Raise position of oating switch
The equipment
does not pump
- Intake sieve clogged
- Discharge hose kinked
- Clean intake sieve with water jet
- Unkink the hose
The equipment
does not cut out
- Floating switch cannot sink - Place equipment correctly on shaft
bottom
Insu cient pumping
rate
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Clean intake sieve
- Clean equipment and replace wear
parts
The equipment swit-
ches o after brie y
running
- Motor circuit-breaker switches the
equipment o due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment o
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
Anl_GC_SP_3580_LL_SPK9.indb 20Anl_GC_SP_3580_LL_SPK9.indb 20 31.01.2019 07:34:1231.01.2019 07:34:12

Table of Contents