EINHELL GE-SP 4390 N-A LL ECO - User Manual

EINHELL GE-SP 4390 N-A LL ECO
24 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
GE-SP 4390 N-A LL ECO
Art.-Nr.: 41.714.40 I.-Nr.: 11029
7
GB Original operating instructions
Clear water pump
םגד הלובט הבאשמל הלעפהו תוחיטב תוארוה
Anl_GE-SP_4390_N-A_LL_ECO_SPK7.indb 1Anl_GE-SP_4390_N-A_LL_ECO_SPK7.indb 1 06.07.2023 11:13:4906.07.2023 11:13:49

Other manuals for EINHELL GE-SP 4390 N-A LL ECO

Questions and Answers

  • V
    Victoria ReedAug 11, 2025
    Why is my EINHELL GE-SP 4390 N-A LL ECO Water Pump not pumping?
    • T
      Thomas ScottAug 11, 2025
      If your EINHELL Water Pump isn't pumping water, start by checking the intake sieve. If it's clogged, clean it with a water jet. Also, inspect the discharge hose to ensure it's not kinked. If it is, unkink the hose to allow proper water flow.
  • R
    Richard BassAug 18, 2025
    What to do if EINHELL GE-SP 4390 N-A LL ECO has insufficient pumping rate?
    • C
      Christopher NewmanAug 18, 2025
      If your EINHELL Water Pump's pumping rate is insufficient, the intake sieve may be clogged. Clean the intake sieve to resolve this. Additionally, heavily contaminated or abrasive water impurities can reduce performance. In this case, clean the equipment and replace any worn parts.
  • L
    Lucas TateAug 25, 2025
    What to do if my EINHELL GE-SP 4390 N-A LL ECO Water Pump switches off after briefly running?
    • B
      brenda18Aug 26, 2025
      If your EINHELL Water Pump switches off shortly after starting, it could be due to a couple of reasons. First, the motor circuit-breaker might be activating because of excessive water contamination; in this case, unplug the power and clean the equipment and shaft. Second, the water temperature may be too high, causing the motor circuit-breaker to switch off the equipment. Make sure the water temperature doesn't exceed 35 °C.
  • K
    Kerry FloydSep 2, 2025
    How to troubleshoot EINHELL Water Pump that does not start?
    • S
      Susan McgeeSep 2, 2025
      If your EINHELL Water Pump isn't starting, begin by checking the power supply to ensure it's properly connected. Also, check the autostart level and ensure it is in the correct position.

EINHELL GE-SP 4390 N-A LL ECO Specifications

General IconGeneral
Max Pressure0.9 bar
Max Suction Depth8 m
Max. delivery height9 m
Max. immersion depth7 m
Max. water temperature35 °C
Max. size of foreign particles5 mm
Mains supply230 V
Voltage230 V
Frequency50 Hz
Cable Length10 m
Max Head9 m
Max Flow Rate9000 L/h
Power cable10 m