GE-WW 1246 N FS
Art.-Nr.: 41.735.30 I.-Nr.: 11018
9
D Originalbetriebsanleitung
Hauswasserwerk
GB Original operating instructions
Home waterworks
F Instructions d’origine
Systemes domestiques de distri-
bution d‘eau
I Istruzioni per l’uso originali
Centralina idrica
DK/ Original betjeningsvejledning
N Husvandværk
S Original-bruksanvisning
Hushållsvattenverk
CZ Originální návod k obsluze
Domácí vodárna
SK Originálny návod na obsluhu
Domáca vodáreň
NL Originele handleiding
Watervoorzieningsinstallatie
E Manual de instrucciones original
Sistema doméstico de bombeo de
agua
FIN Alkuperäiskäyttöohje
Kotitalousvesilaitos
H Eredeti használati utasítás
Házi vízmű
GR Πρωτότυπες Οδηγίες χρήσης
Υδρονομικη οικιακη εγκατασταση
Anl_GE_WW_1246_N_FS_SPK9.indb 1Anl_GE_WW_1246_N_FS_SPK9.indb 1 16.07.2019 14:27:2116.07.2019 14:27:21

Table of Contents

Questions and Answers

  • S
    Shelly PalmerAug 11, 2025
    What to do if EINHELL Water Pump motor fails to start up?
    • K
      Kimberly OliverAug 11, 2025
      If the motor of your EINHELL Water Pump fails to start, there could be a couple of reasons. First, check that there is mains voltage. If voltage is present, the pump rotor may be blocked. If so, dismantle and clean the pump.
  • T
    Tammy JonesAug 18, 2025
    What to do if thermostat switches EINHELL GE-WW 1246 N FS off?
    • A
      Alexander GarciaAug 18, 2025
      If the thermostat is switching your EINHELL Water Pump off, it could be due to the motor being overloaded. In this case, dismantle and clean the pump. Alternatively, excessive friction caused by foreign substances might be the issue. Prevent the intake of foreign substances by using a filter.
  • A
    Andrew FrancisAug 27, 2025
    Why EINHELL GE-WW 1246 N FS Water Pump has no intake?
    • J
      Jason MosesAug 27, 2025
      If your EINHELL Water Pump isn't drawing water, several factors could be at play: * The intake valve may not be submerged; ensure it is fully immersed in water. * The pump chamber might lack a water connection; fill water into the intake. * There could be air in the intake line; ensure the intake line is airtight. * The intake valve might be leaking; try cleaning it. * The strainer could be blocked; clean the strainer. * The maximum suction height might be exceeded; check the suction height.
  • E
    Elizabeth AndrewsSep 2, 2025
    Why EINHELL GE-WW 1246 N FS Water Pump inadequate delivery rate?
    • A
      Anthony AllenSep 2, 2025
      An inadequate delivery rate in your EINHELL Water Pump can stem from several causes: * The suction height may be too high; check and adjust it. * A dirty strainer can impede water flow; clean the strainer. * If the water level is falling rapidly, reposition the suction hose to a deeper level. * Contaminants might diminish pump performance; in this case, clean the pump and replace any worn parts.

EINHELL GE-WW 1246 N FS Specifications

General IconGeneral
Power1200 W
Max Delivery Rate4600 l/h
Max Suction Height8 m
Max. water temperature35 °C
Pressure switchYes
Suction connection1"
Pressure connection1"
Power cord1.5 m
Hose connection1"

Related product manuals