8.1 Servicing
If the equipment becomes clogged, connect
the discharge line to the water line and dis-
connect the suction hose. Open the water
line. Switch on the equipment several times
for approx. two seconds. This should resolve
the majority of clog-related problems.
Inside the pressure tank is an expandable
water sack and an air compartment whose
maximum pressure should lie at approx. 1.5
bar. Pumping water into the water sack cau-
ses the sack to expand so that the pressure in
the air compartment rises to switch-off level. If
the air pressure is too low, you should raise it.
To do so, unscrew the plastic lid from the tank
and top up the pressure to the correct level
using a tyre pump with meter at the valve.
Important: Be sure to completely empty
the water bag first using the water drain
screw (1).
There are no parts inside the equipment
which require additional maintenance.
8.2 Cleaning the coarse lter insert
Clean the coarse filter insert at regular inter-
vals, and replace it if necessary.
Remove the coarse filter screw (4) and coar-
se filter (12) together with the non-return val-
ve (13) (Figure 3).
Do not use abrasive cleaning agents or petrol
to clean the coarse filter and the non-return
valve.
Clean the coarse filter and the non-return val-
ve by tapping them on a flat surface. In cases
of stubborn dirt, first clean with soapy water,
then rinse with clear water and air-dry.
Assemble in reverse order.
8.3 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
9. Disposal and recycling
The equipment is supplied in packaging to pre-
vent it from being damaged in transit. The raw
materials in this packaging can be reused or
recycled. The equipment and its accessories are
made of various types of material, such as metal
and plastic. Never place defective equipment in
your household refuse. The equipment should
be taken to a suitable collection center for proper
disposal. If you do not know the whereabouts of
such a collection point, you should ask in your
local council o ces.
10. Storage
Store the equipment and accessories in a
dark and dry place at above freezing tem-
perature. The ideal storage temperature is
between 5 and 30 °C. Store the electric tool in
its original packaging.
If the pump is not going to be used for a long
time or has to be removed for the winter
months, rinse it out with water, empty it com-
pletely and allow it to dry.
The equipment must be completely drained
before it is subjected to frost.
After long stoppages, make sure the rotor
turns correctly by briefly switching the pump
on and off.
Anl_GE_WW_1246_N_FS_SPK9.indb 19Anl_GE_WW_1246_N_FS_SPK9.indb 19 16.07.2019 14:27:2916.07.2019 14:27:29

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EINHELL GE-WW 1246 N FS and is the answer not in the manual?

EINHELL GE-WW 1246 N FS Specifications

General IconGeneral
BrandEINHELL
ModelGE-WW 1246 N FS
CategoryWater Pump
LanguageEnglish

Related product manuals