EasyManua.ls Logo

EINHELL GE-WW 9041 E - User Manual

EINHELL GE-WW 9041 E
92 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
GE-WW 9041 E
Art.-Nr.: 41.734.44 I.-Nr.: 11036
1
D Originalbetriebsanleitung
Hauswasserwerk
GB Original operating instructions
Home waterworks
F Mode d’emploi d’origine
Systemes domestiques de distri-
bution d‘eau
I Istruzioni per l’uso originali
Centralina idrica
DK/ Original betjeningsvejledning
N Husvandværk
S Original-bruksanvisning
Hushållsvattenverk
HR/ Originalne upute za uporabu
BIH Kućni vodovod
RS Originalna uputstva za upotrebu
Kućni vodovod
CZ Originální návod k obsluze
Domácí vodárna
SK Originálny návod na obsluhu
Domáca vodáreň
Anl_GE_WW_9041_E_SPK1.indb 1Anl_GE_WW_9041_E_SPK1.indb 1 13.12.2016 08:53:1913.12.2016 08:53:19

Table of Contents

Questions and Answers

  • M
    Mark ShawAug 11, 2025
    Why won't my EINHELL GE-WW 9041 E motor start?
    • J
      John LevineAug 11, 2025
      If the motor of your EINHELL Water Pump fails to start, consider these potential causes: - Check that there is mains voltage, and if not, fix it. - The pump rotor may be blocked. If this is the case, dismantle and clean the pump.
  • L
    lawsondianaAug 19, 2025
    How to improve the delivery rate of my EINHELL GE-WW 9041 E?
    • N
      nathan52Aug 19, 2025
      If your EINHELL Water Pump has an inadequate delivery rate, consider the following: - Check that the suction height is not too high. - Clean the strainer if it's dirty. - If the water level is falling rapidly, place the suction hose at a deeper level. - If the pump performance diminished by contaminants part, clean the pump and replace wearing.
  • T
    trevor25Aug 26, 2025
    What to do if the thermostat switches off my EINHELL GE-WW 9041 E?
    • M
      Matthew ValenciaAug 26, 2025
      If the thermostat is switching off your EINHELL Water Pump, it could be due to: - An overloaded motor: dismantle and clean the pump. - Excessive friction from foreign substances: prevent the intake of foreign substances by using a filter.
  • M
    Michael JonesSep 2, 2025
    What to do if my EINHELL GE-WW 9041 E has no intake?
    • A
      Angela GibsonSep 3, 2025
      If your EINHELL Water Pump isn't intaking water, several factors could be at play: - Ensure the intake valve is fully immersed in water. - Verify the pump chamber has a water connection; if not, fill water into the intake. - Confirm the intake line is airtight. - Check and clean the intake valve for any leaks. - Clear any blockages from the strainer. - Make sure that the max suction height is not exceeded.

EINHELL GE-WW 9041 E Specifications

General IconGeneral
Power900 W
Max Flow Rate4100 L/h
Max Suction Height8 m
Max Water Temperature35 °C
Pressure SwitchYes
Protection ClassIPX4
Suction Connection33.3 mm (R1 AG)
Pressure Connection33.3 mm (R1 AG)
Power Cord1.5 m