EasyManua.ls Logo

EINHELL GE-GP 9041 E - User Manual

EINHELL GE-GP 9041 E
92 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
GE-GP 9041 E
Art.-Nr.: 41.822.75 I.-Nr.: 11036
1
D Originalbetriebsanleitung
Gartenpumpe
GB Original operating instructions
Garden pump
F Mode d’emploi d’origine
Pompe de jardin
I Istruzioni per l’uso originali
Pompa per giardino
DK/ Original betjeningsvejledning
N Havepumpe
S Original-bruksanvisning
Trädgårdspump
HR/ Originalne upute za uporabu
BIH Vrtna pumpa
RS Originalna uputstva za upotrebu
Baštenska pumpa
CZ Originální návod k obsluze
Baštenska pumpa
SK Originálny návod na obsluhu
Záhradné čerpadlo
Anl_GE_GP_9041_E_SPK1.indb 1Anl_GE_GP_9041_E_SPK1.indb 1 11.05.2021 09:47:2311.05.2021 09:47:23

Table of Contents

Questions and Answers

  • K
    Kimberly RobertsAug 11, 2025
    Why EINHELL Water Pump motor fails to start up?
    • M
      Meghan SnyderAug 11, 2025
      If the EINHELL Water Pump motor fails to start, the issue could stem from a lack of mains voltage. Ensure you check the voltage supply. Alternatively, the pump rotor might be blocked, in which case you should dismantle and clean the pump.
  • R
    Richard JenkinsAug 19, 2025
    How to improve inadequate delivery rate of EINHELL GE-GP 9041 E?
    • M
      Michelle HardyAug 19, 2025
      If your EINHELL Water Pump's delivery rate is inadequate, start by checking the suction height to ensure it's not too high. Also, inspect the strainer for dirt and clean it if necessary. If the water level is dropping rapidly, reposition the suction hose to a deeper level. Lastly, contaminants might be diminishing the pump's performance, so clean the pump and replace any worn parts.
  • R
    roserobertAug 27, 2025
    What to do if thermostat switches EINHELL GE-GP 9041 E off?
    • C
      contrerasnormaAug 27, 2025
      If the thermostat switches your EINHELL Water Pump off, it could be due to an overloaded motor. Try dismantling and cleaning the pump. Another possible cause is excessive friction from foreign substances. To prevent this, ensure you filter the intake to keep out foreign materials.
  • E
    Erica AcostaSep 2, 2025
    What to do if my EINHELL GE-GP 9041 E has no intake?
    • J
      Jaclyn WilliamsSep 2, 2025
      If your EINHELL Water Pump isn't taking in water, there might be several reasons. First, ensure the intake valve is fully immersed in water. Next, check that the pump chamber is properly filled with water. Also, verify that the intake line is airtight. Clean the intake valve and strainer to remove any blockages. Finally, make sure you haven't exceeded the maximum suction height.

EINHELL GE-GP 9041 E Specifications

General IconGeneral
Power900 W
Max Pressure4 bar
Max Suction Depth8 m
Max Delivery Height40 m
Max Water Temperature35 °C
Max Head40 m
Power Consumption900 W
Protection ClassIP X4
Hose Connection1 inch
Mains supply230 V
Suction Connection1 inch
Pressure Connection1 inch
Power Cord1.5 m
Inlet/Outlet Diameter1 inch

Related product manuals