9. Troubleshooting
Fault Cause Remedy
Engine does not
start
- Spark plug fouled
- Air lter dirty
- No fuel in the tank
- Automatic oil cut-out has not
responded
- Clean or replace the spark plug
- Clean the air lter.
- Top up fuel.
- Check oil level, top up engine oil
Pump fails to prime - Intake valve not in the water
- No water in the pump chamber
- Air in the intake line
- Intake cage (intake valve) blocked
- Max. intake head exceeded
- Place the intake valve in the water
- Fill the pump chamber with water
through the ller neck
- Check the intake line for leaks and
seal it if necessary.
- Clean intake cage
- Check intake head and reduce it if
necessary
Insu cient pumping
rate
- Intake head too high
- Intake cage soiled
- Water level falling rapidly and intake
line is out of the water-
- Pump performance reduced by de-
posits
- Check intake head and reduce it if
necessary
- Clean intake cage
- Place the intake line at a deeper
level
- Clean pump
Important. The pump must not run dry.
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers
accompanying products is permitted only with the express consent of the iSC GmbH.
Subject to technical changes
Anl_GC_PW_16_SPK9.indb 18Anl_GC_PW_16_SPK9.indb 18 24.09.2019 08:45:1324.09.2019 08:45:13

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EINHELL GC-PW 16 and is the answer not in the manual?

EINHELL GC-PW 16 Specifications

General IconGeneral
BrandEINHELL
ModelGC-PW 16
CategoryWater Pump
LanguageEnglish

Related product manuals