11. Troubleshooting guide
Faults Cause Remedy
The equipment
does not start
- Battery is not correctly inserted - Remove battery and insert again
The equipment
does not pump
- Intake sieve clogged
- Discharge hose kinked
- Clean intake sieve with water jet
- Unkink the hose
Insu cient pumping
rate
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Battery performance decreasing
- Clean intake sieve
- Clean equipment and replace wear
parts
- Check the battery performance and
charge the battery if necessary
The equipment swit-
ches o after brie y
running
- Motor circuit-breaker switches the
equipment o due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment o
- Take out the battery and clean the
equipment and the shaft.
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
Anl_GE_DP_18_25_LL_Li_SPK13.indb 22 04.08.2022 10:52:35

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EINHELL GE-DP 18/25 LL Li and is the answer not in the manual?

EINHELL GE-DP 18/25 LL Li Specifications

General IconGeneral
BrandEINHELL
ModelGE-DP 18/25 LL Li
CategoryWater Pump
LanguageEnglish

Related product manuals