EasyManuals Logo

EINHELL GE-GP 1246 N FS User Manual

EINHELL GE-GP 1246 N FS
Go to English
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
GB
- 20 -
11. Troubleshooting guide
Faults Cause Remedy
Motor fails to start
up
- No mains voltage
- Pump rotor blocked -thermostat
switched o
- Check voltage
- Dismantle and clean pump
No intake - Intake valve not in water
- Pump chamber without water con-
nection
- Air in intake line air-tight
- Intake valve leaks
- Strainer (intake valve) blocked
- Max. suction height exceeded
- Immerse intake valve in water
- Fill water into intake
- Make sure intake line is close
- Clean intake valve
- Clean strainer
- Check suction height
Inadequate delivery
rate
- Suction height too high
- Strainer dirty
- Water level falling rapidly
- Pump performance diminishedby
contaminants part
- Check suction height
- Clean strainer
- Place the suction hose at a deeper
level
- Clean pump and replace wearing
Thermostat swit-
ches pump o
- Motor overloaded - friction caused
by foreign substances too high
- Dismantle and clean pump. Prevent
intake of foreign substances ( lter)
Anl_GE_GP_1246_N_FS_SPK9.indb 20Anl_GE_GP_1246_N_FS_SPK9.indb 20 22.07.2019 10:51:5822.07.2019 10:51:58

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EINHELL GE-GP 1246 N FS and is the answer not in the manual?

EINHELL GE-GP 1246 N FS Specifications

General IconGeneral
AC input voltage220-240 V
Power source typeAC
Flow rate4600 l/h
Maximum suction height8 m
Maximum delivery height50 m
Maximum operating pressure5 bar
Maximum input water temperature35 °C
Package depth500 mm
Package width226 mm
Package height370 mm
Quantity per pack1 pc(s)
Cable length1.5 m
Type-
Proper useGarden
Product colorBlack, Red
Suitable for outdoor useYes

Related product manuals