GB
- 28 -
loosely to the saw table.
•
The leg (32) marked (A) must be fastened to
the front left corner of the table, which is whe-
re the On/Off switch (11) is fastened.
•
Fasten the two guide rails (28) to the front and
side of the table at the same time. Use the
Allen screws (b) and nuts (d) to do so.
•
Fasten the rubber feet (13) to the legs using
the countersunk head screws (e) and nuts (f)
•
Fasten the extractor adapter (40) to the ma-
chine.
•
Use the screws (a), washers (c) and nuts (d)
to fasten the cross struts (30) and longitudinal
struts (31) to the legs. Make sure that the
holes in the fitted cross struts and longitudinal
struts face upwards to enable the table length
extension to be fitted later (p. 6.2).
•
Fasten the power cable to the machine frame
using the clip (h).
•
Turn the machine so that it stands on its legs
and then tighten all the screw connections.
6.2 Assembling the handles, tools hook, On/
Off switch, chassis and table length ex-
tension (Fig. 1a, 3a, 3b, 4-7)
•
Fasten the handles (42) and the tool hook
(34) to the front legs
•
Tighten the screw connections on the guide
rails.
•
Fasten the On/Off switch (11) to the leg (32)
using the grub screws (g)
•
Use the hex screws (a), washers (c) and nuts
(d) to screw the chassis (21) to the rear legs.
•
Use the hex screws (a), washers (c) and nuts
(d) to screw the struts (43) to the table length
extension (39).
•
Use the hex screws (a), washers (c) and nuts
(d) to screw the table length extension (39) to
the saw table (1).
•
Use the hex screws (a), washers (c) and nuts
(d) to screw the struts (43) to the rear cross
strut (30).
•
Use the hex screws (a), washers (c) and nuts
(d) to screw the holder (41) for the extraction
hose in position at rear right on the saw table
(see Fig. 1a)
6.3 Fitting / removing the saw blade guard
(Fig. 1, 6-7)
•
Mount the saw blade guard (2) on the splitter
(5) so that the screw fits through the hole (18)
in the splitter.
•
Do not tighten the screw (15) too far – the bla-
de guard must be able to move freely.
•
To remove the saw blade guard, proceed in
reverse order.
Warning!
The guard hood (2) must always be lowered
over the workpiece before you begin to cut.
6.4 Changing the table insert (Figure 8)
•
To prevent increased likelihood of injury the
table insert should be changed whenever it is
worn or damaged.
•
Remove the saw blade guard (2).
•
Remove the 1 countersunk head screws (17).
•
Take out the worn table insert (6).
•
To fit the replacement table insert, proceed in
reverse order.
6.5 Setting the splitter (Fig. 9,10)
•
Danger! Pull out the power plug.
•
Set the blade (4) to max. cutting depth, move
to 0° position and lock in place.
•
Remove the saw blade guard (see 6.2).
•
Take out the table insert (6) (see 6.4).
•
Slacken the fixing screw (19).
•
Push up the splitter (5) until the gap between
the saw table (1) and the upper edge of the
splitter (5) equals approx. 10 cm.
•
The distance between the blade (4) and the
splitter (5) should be 3-5 mm.
•
The gap between the top edge of the splitter
and the highest point of the saw blade should
not exceed a maximum of 2 mm.
•
Retighten the screw (19) and mount the table
insert (6) (Fig. 8).
Anl_TC_TS_2031_U_SPK9-1.indb 28Anl_TC_TS_2031_U_SPK9-1.indb 28 02.12.2019 07:41:4302.12.2019 07:41:43