- 52 -
Chapter 6 Reference
Power Input 100 - 120 VAC ±10 %, 50 / 60 Hz 0.80 A
200 - 240 VAC ±10 %, 50 / 60 Hz 0.50 A
Maximum Power Consumption 47 W or less
Power Save Mode 0.3 W or less (no USB device connected, default settings)
Standby Mode 0.3 W or less (no USB device connected, default settings)
Physical
Specications
Dimensions Min. height:
Max. height:
537.6 mm × 335.1 mm × 278.3 mm (W × H × D) (Tilt: 35˚)
537.6 mm × 473.5 mm × 233 mm (W × H × D) (Tilt: 0˚)
Dimensions (Without Stand) 537.6 mm × 317.6 mm × 47.9 mm (W × H × D)
Net Weight Approx. 6.2 kg
Net Weight (Without Stand) Approx. 3.8 kg
Height Adjustment Range 114.7 mm (Tilt: 35˚) / 140 mm (Tilt: 0˚)
Tilt Up 35˚, down 5˚
Swivel 344˚
Vertical Rotation Left 90˚, right 90˚
Operating
Environmental
Requirements
Temperature 5˚C to 35˚C (41˚F to 95˚F)
Humidity 20% to 80% R.H. (no condensation)
Air Pressure 540 hPa to 1060 hPa
Transportation/
Storage
Environmental
Requirements
Temperature -20˚C to 60˚C (-4˚F to 140˚F)
Humidity 10% to 90% R.H. (no condensation)
Air Pressure 200 hPa to 1060 hPa