DO NOT clean the instrument or cables with any type of
liquids. Cleaning of the instrument to remove overspray and
spots of coatings is a Service requirement. Please contact your
local Distributor or Elcometer Instruments Ltd.
1.2 Do.
DO read these instructions carefully before commencing to
use the equipment.
DO consult the plant or Safety Officer before carrying out the
test procedure.
DO wear rubber gloves.
DO undertake testing well clear of other Personnel.
DO work with an assistant, to keep the test area clear and to
help with the testing procedure.
DO check that there are no solvents or other ignitable materials
in the test area, particularly in confined areas such as tanks.
DO switch the detector off and disconnect the leads when the
work is finished and before leaving it unattended.
DO ensure that the earth lead is connected to the conducting
substrate prior to switching the detector on.
DO only use on coatings which are cured, thickness tested
and visually inspected and accepted.
DO only use on coating thicknesses of at least 200 microns
(0.008"). For thinner coatings, use the wet sponge method with
the Elcometer 204 and 269. Use with care for thicknesses
between 200 and 500 microns (0.008 to 0.020").
DO be aware of static build-up on the work surface. To reduce
the risk of static shock, wear rubber gloves and take special
care when leaving confined areas.
2