Time and date (ST)
Once the appropriate time and date has been set (Menu/Setup/Time
and Date), the user can display the time and date at the top of the
Elcometer 130 display via Menu/Setup/Time and Date/Display
Time and Date.
The time format can be set to either the 12 hour or 24 hour clock via
Menu/Setup/Time and Date/Set Format/Set Time Format
The date format can be set to either dd/mm/yyyy, mm/dd/yyyy or
yyyy/mm/dd via Menu/Setup/Time and Date/Set Format/Set
Date Format
Please note that the time and date is replaced by the batch name
when the gauge is in Batch mode (T).
When a batch is created, re-opened (or when the gauge is switched
on whilst in batch mode) and when each reading is taken, the time
and date details are stored within the batch - allowing the user to have
an accurate record of when the measurements were taken. The time
and date stamp for each reading is displayed in Batch/Review
Batch/Readings by pressing the è softkey and in ElcoMaster™ 2.0.
Gauge Memory (T)
Up to 150,000 readings can be stored into the gauge’s memory either
in a single batch or in up to 2,500 batches (see Batching on page 21).
Each batch can be individually named using the Batch/Edit
Batch/Rename Batch feature on the gauge, see page 22.
www.elcometer.com