HOW TO USE YOUR CAMPERVAN’S EQUIPMENT
Troubleshooting
The significance of the red LED
When operational faults occur the LED flashes a number of times. The number of pulses
depends on the type of fault.
Each flash lasts for one quarter of a second. After the series of impulses a pause follows. The
sequence for the fault is repeated every four seconds.
Number of
flashes
Fault
Possible cause
1
Supply voltage
The supply voltage is outside of the set range.
Excessive fan current
The fan loads the electronics unit with more
than 1A
The motor doesn’t start
The rotor is jammed
The pressure difference in the cooling system
is too high (>5 bar)
2
3
4
Speed too low
If the cooling system is overloaded, the
minimum speed of the motor of 1850 RPM
cannot be maintained.
5
Overheating of the
electronics unit
If the cooling system is overloaded too heavily
or if the temperature is too high, the
electronics can overheat.
Continuous
Temperature not
measurable
NTC sensor is faulty
Fault
Possible cause
Remedy
Compressor runs
constantly
Faulty thermostat
Change the thermostat
Interior temperature too low in temperature level “1”
Compressor runs for a
long time
Large quantities have been
frozen in the freezer
compartment
-
Fault
Possible cause
Remedy
U
KL
= OV
There is an interruption in the
connection between the battery
and the electronics.
Establish a connection
Compressor does not run (battery connection)
-
Main switch faulty (if installed)
Replace the main switch
Additional supply line fuse has
blown (if installed)
Replace the supply line fuse