9-17
HOW TO USE YOUR CAMPERVAN’S EQUIPMENT
Fault
Possible cause
Remedy
No voltage
Interruption in the
supply cable
Establish a connection
Compressor is not running (connected to AC supply)
Main switch faulty (if installed)
Replace the main switch
Additional supply line fuse has
blown (if installed)
Replace the supply line fuse
Voltage is present but
the compressor does
not run
Ambient temperature
too high
-
Insufficient ventilation and/or
air supply
Move the refrigerator to another
location
Condenser is dirty
Clean the condenser
Electric circuit between
the pins in the
compressor interrupted
Defective compressor
Replace the compressor
Fault
Possible cause
Remedy
Compressor runs for a
long time/continuously
Ambient temperature
too high
-
Poor cooling, interior temperature increases
Insufficient ventilation and/or
air supply
Move the refrigerator to another
location
Condenser is dirty
Clean the condenser
Faulty fan
Replace the fan
Compressor runs
intermittently
Battery capacity
exhausted
Charge the battery
Fault
Possible cause
Remedy
Loud humming
A component of the
refrigerant circuit cannot
move freely (touching the
wall)
Bend the component carefully
away from the obstruction
Unusual noises
Foreign body jammed
between the cooling unit and
a wall
Remove the foreign body
Fan noise
-