Alpha SP Series
Indoor Units Outdoor Units
Alpha 9 SP R22 CSP 9 R22
Alpha 12 SP R22 CSP 12 R22
Alpha 9 SP EU R410A CSP 9 R410A EU
Alpha 12 SP EU R410A CSP 12 R410A EU
Alpha 9 SP ISR R410A
CSPI 9 R410A RC
CSPI 9 R410A A2 RC
Alpha 12 SP ISR R410A
CSPI 12 R410A RC
CSPI 12 R410A A2 RC
AUGUST – 2008
REFRIGERANT
R22 COOLING ONLY
R410A
HEAT PUMP
SM ASP 1-E.2 GB
CONTENT

Questions and Answers

  • A
    Andres DeanAug 16, 2025
    Why is my Electra Alpha 12 SP EU R410A Air Conditioner not cooling or heating, and only the indoor fan is working?
    • W
      William JohnsonAug 16, 2025
      If your Electra Air Conditioner is only running the indoor fan and not cooling or heating, it could be due to a faulty outdoor fan motor or another fault causing the compressor overload protection to cut out. Suggested solutions include replacing the P.C.B. and removing any obstructions blocking the outdoor fan.
  • H
    Heather SmithAug 19, 2025
    What to do if Electra Alpha 12 SP EU R410A has no cooling or heating, but indoor fans are working?
    • A
      Arthur VillarrealAug 19, 2025
      If your Electra Air Conditioner isn't cooling or heating, but the indoor fans are working, it could be due to a few reasons: * The overload safety device on the compressor might be cut out because of low voltage or high temperature. In this case, check for proper voltage, switch off the power, and try again after one hour. * The compressor run capacitor might be faulty; consider replacing it. * The compressor windings could be shorted, requiring you to replace the compressor.
  • M
    Michelle BaileyAug 22, 2025
    Why is my Electra Alpha 12 SP EU R410A Air Conditioner only blowing air from the indoor fan?
    • C
      Christopher JenkinsAug 22, 2025
      If your Electra Air Conditioner is only running the indoor fan, it could be due to: * A faulty run capacitor of the outdoor fan motor. Replace the capacitor. * Shorted windings of the outdoor fan. Replace the motor.
  • D
    Danielle BradfordAug 26, 2025
    What to do if Electra Air Conditioner has only indoor fan and compressor working?
    • K
      Kevin AveryAug 26, 2025
      If your Electra Air Conditioner has only the indoor fan and compressor working, it's likely that the outdoor fan is blocked. Remove any obstructions to resolve this issue.
  • P
    pfisherAug 28, 2025
    What to do if my Electra Alpha 12 SP EU R410A Air Conditioner has no air supply at the indoor unit, but the compressor operates?
    • X
      xwilkinsAug 28, 2025
      If there's no air supply at the indoor unit of your Electra Air Conditioner, but the compressor is running, it could be because: * The indoor fan motor is blocked or turning slowly. Check the voltage and repair the wiring if necessary. Also, check if the fan wheel is tight enough on the motor shaft, and tighten it if needed. * The indoor fan run capacitor is faulty. * The motor windings are shorted.
  • R
    Richard MontgomeryAug 31, 2025
    What to do if Electra Alpha 12 SP EU R410A is in heat mode but operating in cooling?
    • K
      kathryn31Aug 31, 2025
      If your Electra Air Conditioner is in heat mode but operating in cooling, it could be caused by a faulty RV coil or the RV valve being stuck. To resolve this, you can replace the RV coil or replace the reversing valve.
  • R
    Rachel MorrisSep 3, 2025
    Why is my Electra Air Conditioner's outdoor coil freezing up in heating mode?
    • J
      jonathan74Sep 3, 2025
      If the outdoor coil of your Electra Air Conditioner is freezing up in heating mode, and the heating effect in the room is poor, with the indoor fan operating, it could be due to several reasons: * A faulty outdoor thermistor: Replace the thermistor. * A faulty control cable: Repair the control cable. * Outdoor temperature below design conditions: Shut the unit off, as it cannot work properly under these conditions. * A blocked outdoor unit air outlet: Remove any obstructions.
  • K
    Kimberly JacksonSep 6, 2025
    What to do if Electra Alpha 12 SP EU R410A Air Conditioner has a limited air supply at the indoor unit?
    • A
      alyssaestradaSep 6, 2025
      If your Electra Air Conditioner has a partial or limited air supply at the indoor unit, it's likely due to a lack of refrigerant, which may also cause a whistling noise and ice formation on the indoor unit coil in cooling mode. To fix this, charge the unit after localizing the leak.
  • E
    Elizabeth Perez DVMSep 9, 2025
    What to do if water is dripping from the outdoor unit base of my Electra Alpha 12 SP EU R410A in heating mode?
    • C
      cparsonsSep 9, 2025
      If water is dripping from the outdoor unit base of your Electra Air Conditioner while in heating mode, it's likely that the water drain outlet is clogged. To resolve this, open the outdoor unit cover, clean out the water outlet, and thoroughly clean the base inside.
  • B
    Brian CookSep 12, 2025
    What to do if water accumulates and overflows from the indoor unit section of my Electra Alpha 12 SP EU R410A?
    • J
      James WhiteSep 13, 2025
      If water is accumulating and overflowing from the indoor unit section of your Electra Air Conditioner, the drain tube or spout of the drain pan is likely clogged. Disassemble the plastic drain tube from the spout of the indoor unit drain pan to clear the clog.

Summary

Product Data Sheet

Alpha 9 SP R22; CSP 9 R22 Specifications

Technical specifications for the Alpha 9 SP R22 and CSP 9 R22 models.

Alpha 12 SP R22; CSP 12 R22 Specifications

Technical specifications for the Alpha 12 SP R22 and CSP 12 R22 models.

Alpha 9 SP EU R410 A; CSP 9 EU R410 A Specs

Technical specifications for the Alpha 9 SP EU R410A and CSP 9 EU R410A.

Alpha 12 SP EU R410 A; CSP 12 SP EU R410 A Specs

Technical specifications for the Alpha 12 SP EU R410A and CSP 12 SP EU R410A.

Alpha 9 SP ISR R410 A; CSPI 9 R410 A RC A1 Specs

Technical specifications for the Alpha 9 SP ISR R410A and CSPI 9 R410A RC A1.

Alpha 12 SP ISR R410 A; CSPI 12 R410 A RC A1 Specs

Technical specifications for the Alpha 12 SP ISR R410A and CSPI 12 R410A RC A1.

ASP 9 R410 A A2 ISR; CSPI 9 R410 A A2 ISR Specs

Technical specifications for the ASP 9 R410A A2 ISR and CSPI 9 R410A A2 ISR.

ASP 12 R410 A A2 ISR; CSPI 12 R410 A A2 ISR Specs

Technical specifications for the ASP 12 R410A A2 ISR and CSPI 12 R410A A2 ISR.

Rating Conditions

Performance Data & Pressure Curves

R22 Models Performance Data

Performance data tables for Alpha/CSP 9/12 R22 models.

R22 Models Pressure Curves

Pressure curves for Alpha/CSP 9/12 R22 models.

R410 A EU Models Performance Data

Performance data tables for Alpha/CSP 9/12 R410A EU models.

R410 A EU Models Pressure Curves

Pressure curves for Alpha/CSP 9/12 R410A EU models.

R410 A ISR Models Performance Data

Performance data tables for Alpha/CSP 9/12 R410A ISR models.

R410 A ISR Models Pressure Curves

Pressure curves for Alpha/CSP 9/12 R410A ISR models.

R410 A A2 ISR Models Performance Data

Performance data tables for Alpha SP 9/12 R410A A2 ISR models.

R410 A A2 ISR Models Pressure Curves

Pressure curves for Alpha SP 9/12 R410A A2 ISR models.

Electrical Data

Wiring Diagrams

Indoor Unit Wiring Diagram (ASP9,12)

Wiring diagram for the ASP9 and ASP12 indoor units.

Outdoor Unit Wiring Diagram (CSP9, 12)

Wiring diagram for the CSP9 and CSP12 outdoor units.

Electrical Connections

Refrigeration Diagrams

Heat Pump Models Refrigeration

Refrigeration cycle diagrams for heat pump models in cooling and heating modes.

Cooling Only Models Refrigeration

Refrigeration cycle diagram for cooling-only models.

Control System ASP9, ASP12

12.1 Electronic Control

Overview of electronic control features, including introduction and jumper settings.

12.3 General Functions

Details on compressor, fan, heating element, and protection operations.

12.4 Cooling Mode Operation

General principles for cooling mode, including autofan and general operation.

12.8 Protection Modes

Details on cooling and heating mode protection mechanisms like defrost and pressure protection.

Troubleshooting

Exploded Views and Spare Parts Lists

Electra Alpha 12 SP EU R410A Specifications

General IconGeneral
BrandElectra