Service Manual
WNG LED/LCD Series
REFRIGERANT
R410A
R407C
R22
COOLING ONLY
HEAT PUMP
SEPTEMBER - 2005
Indoor Units Outdoor Units
WNG 7 GCN 7 ONG 7
WNG 9 GCN 9 ONG 9
WNG 12 GCN 12 ONG 12
WNG 14 GC 14 ONG 14
WNG 18 GC 18
WNG 21 GC 22
WNG 24 OU7-24
WNG 25 GC 24
WNG 30 GC 30 OU8 30/33
WNG 36 OU10-36

Table of Contents

Questions and Answers

  • C
    cgreenSep 8, 2025
    What causes water to accumulate and overflow from the indoor unit of my Electra GCN 12?
    • J
      jenniferhigginsSep 8, 2025
      If water is accumulating and overflowing from the indoor unit section of your Electra Air Conditioner, the drain tube or spout of the drain pan may be clogged. Disassemble the plastic drain tube from the spout of the indoor unit drain pan.
  • B
    broseAug 23, 2025
    What to do if the indoor fan on my Electra Air Conditioner is not functioning correctly?
    • M
      Matthew FloresAug 23, 2025
      If the indoor fan of your Electra Air Conditioner is not functioning correctly, check the voltage between the indoor fan terminals on the main P.C.B. If there is voltage, replace the capacitor or motor.
  • C
    Christine LozanoAug 25, 2025
    How to fix Electra Air Conditioner refrigeration system not working correctly?
    • S
      sharonhodgeAug 25, 2025
      If the refrigeration system in your Electra Air Conditioner isn't functioning correctly, check for leaks or restrictions using an ammeter, pressure gauge, or surface thermometer. Repair the refrigeration system and charge refrigerant if necessary.
  • D
    Danielle GillespieAug 27, 2025
    Why is the Electra GCN 12 outdoor fan not working correctly?
    • T
      Trevor SmithAug 27, 2025
      If the outdoor fan of your Electra Air Conditioner isn't working correctly, check the voltage between the outdoor fan terminals on the main P.C.B. If there is no voltage, replace the main P.C.B. If voltage is present, replace the capacitor or motor. Also, check and repair the electrical wiring between the indoor and outdoor units.
  • A
    amyhurstAug 27, 2025
    What to do if Electra Air Conditioner indoor fan is not working correctly?
    • E
      Erica AllenAug 27, 2025
      If the indoor fan of your Electra Air Conditioner isn't functioning correctly, check the voltage between the indoor fan terminals on the main P.C.B. If there is voltage, replace the capacitor or motor.
  • D
    Dr. Jason WrightSep 22, 2025
    How to fix the red stand-by light on an Electra GCN 12 Air Conditioner?
    • N
      nicoleconnerSep 22, 2025
      If the red stand-by indicator light on the central control display panel of your Electra Air Conditioner isn’t lighting up, it could be due to incorrect voltage between the line and neutral terminals on the main P.C.B. If the voltage is low, repair the power supply; if there's no voltage, repair the general wiring; if the voltage is correct, replace the main or display P.C.B’s.
  • K
    Kimberly LiuSep 16, 2025
    What to do if the Electra Air Conditioner compressor doesn't start?
    • N
      Nicholas StoneSep 16, 2025
      If the compressor on your Electra Air Conditioner isn't starting, check the voltage on the compressor terminals on the outdoor unit using an ammeter. If there's no voltage, replace the main P.C.B. If the voltage is low, repair the power supply. If the voltage is correct, replace the capacitor or compressor. If there is no voltage, repair electrical wiring between indoor and outdoor units.
  • S
    Susan WoodardSep 18, 2025
    What if the Electra GCN 12 green light doesn't turn on when starting from the unit?
    • L
      Laura GarciaSep 18, 2025
      If the green operation indicator light doesn't light up when starting your Electra Air Conditioner from the unit, check the main P.C.B and display P.C.B. Replace the P.C.B if necessary.
  • T
    terri17Sep 7, 2025
    Why is my Electra GCN 12 in heat mode but operating in cooling?
    • K
      Kelsey GreenSep 7, 2025
      If your Electra Air Conditioner is set to heat mode but is operating in cooling, the RV coil may be faulty, or the valve is stuck in position. Replace the RV coil, or replace the reversing valve.
  • M
    Matthew KelleySep 4, 2025
    Why is there only a partial air supply at the indoor unit of my Electra GCN 12 Air Conditioner?
    • G
      garrettlindaSep 4, 2025
      If you're experiencing a partial or limited air supply at the indoor unit of your Electra Air Conditioner, it could be due to a lack of refrigerant, which may also cause a whistling noise and ice formation on the indoor unit coil in cooling mode. Charge the unit after localizing the leak.