Service Manual
WNG LED/LCD Series
REFRIGERANT
R410A
R407C
R22
COOLING ONLY
HEAT PUMP
SEPTEMBER - 2005
Indoor Units Outdoor Units
WNG 7 GCN 7 ONG 7
WNG 9 GCN 9 ONG 9
WNG 12 GCN 12 ONG 12
WNG 14 GC 14 ONG 14
WNG 18 GC 18 —
WNG 21 GC 22 —
WNG 24 OU7-24 —
WNG 25 GC 24 —
WNG 30 GC 30 OU8 30/33
WNG 36 OU10-36 —

Table of Contents

Questions and Answers

  • L
    Leslie ParkerAug 21, 2025
    How to fix Electra GCN 12 with only indoor fan working and no cooling or heating?
    • A
      Angela NunezAug 21, 2025
      If your Electra Air Conditioner is only blowing air from the indoor fan but not cooling or heating, the outdoor fan motor may be faulty, or another issue may have caused the compressor overload protection to cut out. Replace the P.C.B. Also, check if the outdoor fan is blocked and remove any obstructions.
  • M
    Matthew KelleySep 4, 2025
    Why is there only a partial air supply at the indoor unit of my Electra GCN 12 Air Conditioner?
    • G
      garrettlindaSep 4, 2025
      If you're experiencing a partial or limited air supply at the indoor unit of your Electra Air Conditioner, it could be due to a lack of refrigerant, which may also cause a whistling noise and ice formation on the indoor unit coil in cooling mode. Charge the unit after localizing the leak.
  • K
    Krista RoblesSep 2, 2025
    What could cause my Electra Air Conditioner refrigeration system to not function correctly?
    • A
      Angela GrahamSep 2, 2025
      If the refrigeration system in your Electra Air Conditioner isn't working right, check for leaks or restrictions using an ammeter, pressure gauge, or surface thermometer. Then, repair the refrigeration system and charge refrigerant if needed.
  • S
    Sarah StewartSep 1, 2025
    Why is there no air supply at the indoor unit of my Electra GCN 12 Air Conditioner, even though the compressor is running?
    • A
      annandrewsSep 1, 2025
      If there's no air supply at the indoor unit of your Electra Air Conditioner while the compressor is running, the indoor fan motor might be blocked or turning slowly, the indoor fan run capacitor might be faulty, or the motor windings could be shorted. Check the voltage and repair the wiring if necessary. Also, check if the fan wheel is tight enough on the motor shaft and tighten it if necessary.
  • R
    Randy PhillipsAug 30, 2025
    What causes the outdoor fan on my Electra GCN 12 to not function correctly?
    • A
      Antonio WrightAug 30, 2025
      If the outdoor fan on your Electra Air Conditioner isn't working right, check the voltage between the outdoor fan terminals on the main P.C.B. If there is no voltage, replace the main P.C.B. If there is voltage, replace the capacitor or motor. Additionally, inspect and repair the electrical wiring between the indoor and outdoor units.
  • L
    Linda GalvanAug 29, 2025
    Why won't the compressor start on my Electra GCN 12?
    • P
      patrick25Aug 29, 2025
      If the compressor on your Electra Air Conditioner isn't starting, first check the voltage on the compressor terminals on the outdoor unit using an ammeter to see if there is correct voltage. If there's no voltage, replace the main P.C.B. If the voltage is low, repair the power supply. If the voltage is correct, replace the capacitor or the compressor. If there is still no voltage, then repair the electrical wiring between the indoor and outdoor units.
  • A
    amyhurstAug 27, 2025
    What to do if Electra Air Conditioner indoor fan is not working correctly?
    • E
      Erica AllenAug 27, 2025
      If the indoor fan of your Electra Air Conditioner isn't functioning correctly, check the voltage between the indoor fan terminals on the main P.C.B. If there is voltage, replace the capacitor or motor.
  • D
    Danielle GillespieAug 27, 2025
    Why is the Electra GCN 12 outdoor fan not working correctly?
    • T
      Trevor SmithAug 27, 2025
      If the outdoor fan of your Electra Air Conditioner isn't working correctly, check the voltage between the outdoor fan terminals on the main P.C.B. If there is no voltage, replace the main P.C.B. If voltage is present, replace the capacitor or motor. Also, check and repair the electrical wiring between the indoor and outdoor units.
  • C
    Christine LozanoAug 25, 2025
    How to fix Electra Air Conditioner refrigeration system not working correctly?
    • S
      sharonhodgeAug 25, 2025
      If the refrigeration system in your Electra Air Conditioner isn't functioning correctly, check for leaks or restrictions using an ammeter, pressure gauge, or surface thermometer. Repair the refrigeration system and charge refrigerant if necessary.
  • B
    broseAug 23, 2025
    What to do if the indoor fan on my Electra Air Conditioner is not functioning correctly?
    • M
      Matthew FloresAug 23, 2025
      If the indoor fan of your Electra Air Conditioner is not functioning correctly, check the voltage between the indoor fan terminals on the main P.C.B. If there is voltage, replace the capacitor or motor.

Electra GCN 12 Specifications

General IconGeneral
BrandElectra
ModelGCN 12
CategoryAir Conditioner
LanguageEnglish