- 13 -
Spares Operation - R.Kurzke 02/05 599 521 951 EN
Power supply interruption during water fill
If the water fill phase is interrupted by opening the door or due to a power failure, the
contents of the counters are stored in memory; when the door is re-closed or when the
power supply is restored, the water fill resumes from the point at which it was interrupted;
the new counter values are added to those previously memorized.
8. Static filling
- Static filling until pressure switch point.
failure code:
If this point isnt reached after max. 2 minutes, a failure code is displayed and the pro-
gram is stopped.
7. Water Inlet
The water flows into the regeneration dosage chamber via inlet valve, over air break, into regeneration
dosage chambers and into softener
The level control chamber built into the sump operates the pressure switch.