Spares Operation - R.Kurzke 02/05 599 521 951 EN
Customers menu: Water hardness
With this procedure it is possible to modify the regeneration level selection (depending on the water
hardness).
Regeneration selection
To activate the function:
1. Press and hold down button S1.
2. Turn the knob to Position 1:
- The LEDs LD0 and LD1 flash
- Release button S1
3. Press button S1
- The regeneration level is displayed by the End of cycle
LED which flashes and pauses at intervals: for the
decodification, see summary table of alarms.
Press button S1 to increase the regeneration level
according to the following values: