- 26 -
Spares Operation - R.Kurzke 02/05 599 521 951 EN
To dismount the leach pump, the hose clamps are
released and the screws removed.
The flooding switch is snapped out with
a small screwdriver and can be taken
out of its mounting.
After removing the protective cap, the
microswitch can be snapped out.
Here you can see how
the hose clamps can be
re-tensioned with wire
cutting pliers.