EDW 7100
Q&CI Technical Support – RA
Chapter 3.1
LED Test / Delete Alarm Memory
After accessed Service mode (L1, L2 and L3 blinking):
1. Press button S2 to start this function.
All used LEDs/icons blink 5 second on 1 second off.
If a buzzer is equipped, it beeps for 5 seconds.
The alarm codes saved in memory are erased.
2. Switching off the appliance by pressing On/Off button (S0) will exit Service mode.
Functional Test Cycle
After accessed Service mode (L1, L2 and L3 blinking):
1
. Press button S3 to start the test cycle. The cycle will not start if door is opened.
All LEDs under “MYTIME” are on for the duration of the test cycle.
The test cycle runs as a normal wash cycle. It can be cancelled or run to its end.