The top lamp
Step 1
Turn the lamp glass cover to remove it.
Step 2 Clean the glass cover.
Step 3 Remove the metal ring and clean the glass cover.
Step 4 Replace the lamp with a suitable 300 °C heat-resistant lamp.
Step 5 Attach the metal ring to the glass cover.
Step 6 Install the glass cover.
The side lamp
Step 1 Remove the left shelf support to get access to the lamp.
Step 2 Use a Torx 20 screwdriver to remove the cover.
Step 3 Remove and clean the metal frame and the seal.
Step 4 Replace the lamp with a suitable 300 °C heat-resistant lamp.
Step 5 Install the metal frame and the seal. Tighten the screws.
Step 6 Install the left shelf support.
48/64