- 17 -
DGN-TDS-N 11.03 U. H. / A. B. © Electrolux 599 512 232 EN
9
9
P
6
/9
P





6
P
After
1 Min
4.9 Power Management
- Power management – actual status
This is due to the limited power on 1 phase (3,7kW for induction). The last selected cooking
zone has priority and gets the power. The user interface sends a HobUserSelection message
with the required power level. If the power board is unable to do this, the other zone is set to a
lower level by the power board this is broadcast to the user interface with Hob Power Mana-
gement actual status message.
- The user interface displays blinking the set value and the actual value. If the power is not set
to the full set value during 1 Min. the user interface changes the set value to the lower actual
value (HobUserSelection Message).
- PowerManagement with Stop & Go: If the Stop & Go functionality is used in the 1
st
minute
of the PowerManagement, the managed cookinglevels were selected after relesing the Stop&
Gop functionality.
After
- Remark: the power function is switched off automatically after 10 Min. from the induction
power board and the power level is set to 9. In this case there is no switch between actual
and set value, the actual value is displayed. A power reduction is also possible due to a too
low cooling performance of the induction module. This case is handled in the same way.
Same procedure if there is a reduction due to too high temperature at the coil sensor.