INSTALLATION INSTRUCTIONS | SMART LINE BOILING PAN
EN | 10-2018 DOC N° ST0 9183-02 23
12.4 Boiling pans SM6B, SM6V,
SM6P
12.4.1 Single Stand 50L, 80L and 100L
1 Fixtures: PNC 928029
2 Alternative direction of drainage
12.4.2 Right column 50L 80L and 100L
Connections:
A Hot water: DN15 (G1/2”) internal thread
B Cold water: DN20 (G3/4”) male thread
C Electrical cable
D Shut-off valves (not supplied)
E Joints between electrical cables and pipes are
sealed
F Min. cable length 0.75 m.
G Front edge of frame
H Steam connection, 110-170 kPa (1.1-1.7 bar)
Steam-heated pans: DN20 (G3/4”) Internal thread
I Condensation connection (Steam-heated pans):
DN20 (G3/4”) Internal thread
In case of alternative connection from the rear:
a Hot water: DN15 (G1/2”) internal thread
b Cold water: DN20 (G3/4”) male thread
c Electrical cable
50L 80L 100L
R 595 763 763
K 400 600 600
L 700 900 900
M 565 710 710
N 1245 1375 1420
T 250 305 305
U 135 190 190
Fig. 5