13
Programming
T4190, T4250, T4350, T4300S, T4300LE
0 01 High temperature 30 - 70°C 1°C 70 Air outlet temperature High
0 02 Medium temperature 30 - 70°C 1°C 60 Air outlet temperature Medium
0 03 Low temperature 30 - 70°C 1°C 50 Air outlet temperature Low
T4290, T4530, T4650, T4900, T41200
0 01 High temperature 30 - 80°C 1°C 80 Air outlet temperature High
0 02 Medium temperature 30 - 80°C 1°C 70 Air outlet temperature Medium
0 03 Low temperature 30 - 80°C 1°C 50 Air outlet temperature Low
0 04 No heat temperature - - -
0 05 Discount 0 - 99 mins. 1 min. 5 Only on coin operated dryers
0 06 Time per push or coin 1 1 – 90 mins. 1 min. 15 Time interval
0 07 Time per coin 2 1 – 90 mins. 1 min. 30 Time interval
0 08 Min. time before start 0 – 90 mins. 1 min. 0 Only on dryers with payment
1 01 Hour counter 0 – 999999 hrs. - 0 Permanent total hour counter
1 02 Hour counter 0 – 999999 hrs. - 0 Resettable trip hour counter
1 03 Service hour counter 0 – 999999 hrs. - 0 Hours before next service
1 04 Coin counter 1 0 – 999999 coins - 0 Total no. of coins inserted (coin type1)
1 05 Coin counter 2 0 – 999999 coins - 0 Total no. of coins inserted (coin type 2)
To move from group 0 to group 1 press <Return> till 0
- -
and then press <Up> until 1
- -
The outlet temperature in parameters 0 01 - 0 03
must have a max. setting of 70°C
Parameter overview- Area A
Group 0 - Setting temperatures and drying time
Para-
meter
Designation
Range
Step
Factory
setting
Comments
Group 1 - Reading total counters
Para-
meter
Designation
Range
Step
Factory
setting
Comments