14
Programming
Error codes overview
Error Description
code
E 01 Not in use
E 02 Not in use
E 03 The input sensor has short circuited
The thermistor that measures air temperature at the drum inlet or the wires running to
the sensor has short circuited.
E 04 The output sensor has short circuited
The thermistor that measures air temperature at the drum outlet or the wires running
to the sensor has short circuited.
E 05 The fan motor has overheated (Motor 1)
The heat protection contact in the motor, or its cable stem, is open.
E 06 The drum motor has overheated (Motor 2)
The heat protection contact in the motor, or its cable stem, is open.
E 07 External error
E 08 Machine overheated
Protectionthermostatsforinletandoutletair.
One of the protection thermostats has opened due to overheating.
E 09 Filter lid open
E 10 Incorrect programming
One or more parameters are incorrect or is missing.
E 11 Drying error with RMC program
ThelongestpermittedRMCtimehasbeenexceeded.
(AppliesonlytomachineswithRMC).
E 12 Drying error with autostop program
Thelongestpermittedautomaticstoptimehasbeenexceeded.
(Appliesonlytomachineswithautomaticstop).
E 13 Drying error with time program
Thesetdryingtimeislongerthanlongestpermitted.
(Appliestotumbledryersthatareconnectedtoapaymentsystem).
E 14 Gas error, push gas reset button
Noamehasbeendetected.(Appliesonlytogasheatedtumbledryers).
E 15 No vacuum detected
The vacuum/pressure switch does not close within 12 seconds of the tumble
dryerstarting.
E 16 Vacuum sensor has short circuited
The vacuum/pressure switch was already closed when an attempt was made
tostartthetumbledryer.
E 17 The input sensor has disconnected
Theinletthermistor,oritswires,isopen.
E 18 The output sensor has disconnected
The outlet thermistor, or its wires, is open.